{"id":4883,"date":"2025-10-04T09:21:49","date_gmt":"2025-10-04T01:21:49","guid":{"rendered":"https:\/\/aquarainwater.com\/?page_id=4883"},"modified":"2025-12-12T15:40:27","modified_gmt":"2025-12-12T07:40:27","slug":"geomembranes","status":"publish","type":"page","link":"https:\/\/aquarainwater.com\/fr\/products\/geomembranes\/","title":{"rendered":"G\u00e9omembranes"},"content":{"rendered":"<div class=\"wp-block-uagb-container uagb-block-d1d01412 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-eda6709c\">\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-391a5e77\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap\">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-66335680 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">DIRECTEMENT DE L'USINE \u2022 OEM\/ODM<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-8622412f\"><h3 class=\"uagb-heading-text\"><strong>Rev\u00eatements g\u00e9omembranes en PEHD et PEHD-L pour <strong>R\u00e9tention des eaux pluviales<\/strong>, D\u00e9charges et exploitation mini\u00e8re<\/strong><\/h3><p class=\"uagb-desc-text\">G\u00e9omembranes robustes en PEHD et PEBDL pour cellules de d\u00e9charge, bassins de lixiviation, confinement des eaux us\u00e9es et confinement secondaire. Con\u00e7ues pour r\u00e9pondre aux normes GRI GM13\/GM17 et aux principales normes de performance ASTM\/ISO, avec des options de rev\u00eatements lisses, textur\u00e9s, r\u00e9fl\u00e9chissants (blancs\/noirs) et conducteurs pour la d\u00e9tection des fuites.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-37bb93c8\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap\">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-add3b512 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">GRI GM13 \/ GM17 \u2014 Test\u00e9 conform\u00e9ment aux exigences<\/div><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-7f602939 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">ASTM D6693 \u2022 D4833 \u2022 D1004 \u2022 D6392 \u2014 Test\u00e9<\/div><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-729f04cb wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">Sous-titre D de l'EPA (\u00c9tats-Unis) \u2014 Pr\u00eat \u00e0 l'emploi<\/div><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-3e110eb6 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">EN 13361 \/ EN 13491 (UE) \u2014 Pr\u00eat \u00e0 l'emploi<\/div><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-9d4d5652 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">Certifi\u00e9 ISO 9001 \/ 14001 \/ 45001<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-54529762\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap\">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-2a6f4206 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/aquarainwater.com\/fr\/contact\/\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">Obtenir un devis<\/div><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-781c28fd wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#standardspecifications\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">Voir les sp\u00e9cifications<\/div><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-65f18f32 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"#\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">D\u00e9lai de livraison : 2 \u00e0 4 semaines | Exp\u00e9dition internationale<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-5a7c5ef7\">\n<div class=\"wp-block-uagb-image uagb-block-ac3d83ba wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp ,https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp 780w, https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp\" alt=\"G\u00e9omembranes en PEHD et PEHD-L pour le confinement des d\u00e9charges, les bassins de lixiviation mini\u00e8re et les lagunes d&#039;eaux us\u00e9es\" class=\"uag-image-5745\" width=\"1600\" height=\"1069\" title=\"G\u00e9omembranes en PEHD et PEHD-L pour le confinement des d\u00e9charges, les bassins de lixiviation mini\u00e8re et les lagunes d&#039;eaux us\u00e9es\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div data-aos= \"fade-down\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-bd0524fa alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-layout-flex uagb-block-efefa861 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-ad5b0e6b\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-789cd34e\"><h2 class=\"uagb-heading-text\"><strong>Pourquoi choisir nos g\u00e9omembranes ?<\/strong><\/h2><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Performance barri\u00e8re \u00e9prouv\u00e9e<\/strong>&nbsp;avec une conductivit\u00e9 hydraulique extr\u00eamement faible, caract\u00e9ristique des rev\u00eatements en PEHD utilis\u00e9s dans les syst\u00e8mes techniques.<\/li>\n\n\n\n<li><strong>Haute r\u00e9sistance chimique<\/strong>&nbsp;contre les acides, les alcalis, les sels et de nombreux liquides utilis\u00e9s dans les processus industriels.<\/li>\n\n\n\n<li><strong>Stabilis\u00e9 aux UV<\/strong>&nbsp;avec 2\u20133% noir de carbone pour une exposition prolong\u00e9e \u00e0 l'ext\u00e9rieur.<\/li>\n\n\n\n<li><strong>Soudable et r\u00e9parable<\/strong>: le soudage \u00e0 coin chaud et par extrusion permet d'obtenir des joints solides et inspectables.<\/li>\n\n\n\n<li><strong>D\u00e9ploiement rapide<\/strong>&nbsp;utiliser des rouleaux larges (jusqu'\u00e0 environ 8 m\/26 pieds) pour minimiser les joints sur le terrain.<\/li>\n\n\n\n<li><strong>Dimensions personnalis\u00e9es pour les r\u00e9servoirs :<\/strong> Nous pouvons pr\u00e9d\u00e9couper ou pr\u00e9fabriquer des rev\u00eatements adapt\u00e9s aux dimensions sp\u00e9cifiques de votre r\u00e9servoir de r\u00e9tention, ce qui r\u00e9duit le temps de soudage sur site.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-3a6b18b3\">\n<div class=\"wp-block-uagb-image uagb-block-75d1b2e8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Why-Choose-Our-Geomembranes-1024x640.webp ,https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Why-Choose-Our-Geomembranes.webp 780w, https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Why-Choose-Our-Geomembranes.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Why-Choose-Our-Geomembranes-1024x640.webp\" alt=\"Rouleau de g\u00e9omembrane en PEHD haute durabilit\u00e9 pr\u00e9sentant une r\u00e9sistance chimique et une stabilit\u00e9 aux UV pour un confinement \u00e0 long terme\" class=\"uag-image-5934\" width=\"1024\" height=\"640\" title=\"Rouleau de g\u00e9omembrane en PEHD haute durabilit\u00e9 pr\u00e9sentant une r\u00e9sistance chimique et une stabilit\u00e9 aux UV pour un confinement \u00e0 long terme\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div data-aos= \"fade-down\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-9d7ad5dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-8d828050 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-d01ceeee\"><h2 class=\"uagb-heading-text\"><strong>Mat\u00e9riaux et options de surface<\/strong><\/h2><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-dbbc7df6 default uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-block-47724a14\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-5bc7515c\"><h3 class=\"uagb-heading-text\"><strong><a href=\"https:\/\/geosynthetic-institute.org\/grispecs\/gm13.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">PEHD (GRI GM13)<\/a><\/strong><\/h3><p class=\"uagb-desc-text\">La g\u00e9omembrane en PEHD offre la meilleure r\u00e9sistance chimique et la meilleure durabilit\u00e9 de sa cat\u00e9gorie pour les d\u00e9charges, les mines et le confinement \u00e0 long terme. Elle est disponible en version lisse ou textur\u00e9e (sur une ou deux faces) avec une \u00e9paisseur de 0,75 \u00e0 3,0 mm (30 \u00e0 120 mil) et une formulation stabilis\u00e9e aux UV avec une densit\u00e9 \u2265 0,940 g\/cm\u00b3 selon la norme GM13.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8b6ebaf2\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-e8e344e0\"><h3 class=\"uagb-heading-text\"><strong><a href=\"https:\/\/geosynthetic-institute.org\/grispecs\/gm17.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">LLDPE (GRI GM17)<\/a><\/strong><\/h3><p class=\"uagb-desc-text\">La g\u00e9omembrane LLDPE offre une plus grande flexibilit\u00e9 et une meilleure conformit\u00e9 au sol de fondation pour les zones sujettes au tassement, les lagunes et la mise en place par temps froid. Elle est disponible en version lisse ou textur\u00e9e, avec une \u00e9paisseur de 0,75 \u00e0 3,0 mm (30 \u00e0 120 mil), et a \u00e9t\u00e9 test\u00e9e selon la norme GM17 avec des rapports ASTM\/ISO \u00e0 l'appui.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-be119500\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-4bd6ecd7\"><h3 class=\"uagb-heading-text\"><strong>Blanc\/Noir coextrud\u00e9<\/strong><\/h3><p class=\"uagb-desc-text\">La doublure coextrud\u00e9e \u00e0 dessus blanc et c\u0153ur noir r\u00e9duit l'absorption de chaleur et aide \u00e0 contr\u00f4ler les plis sur les travaux expos\u00e9s tout en conservant une durabilit\u00e9 UV \u00e0 long terme. Elle peut \u00eatre produite en PEHD ou en PEFL.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-d106e4ed\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-7048176f\"><h3 class=\"uagb-heading-text\"><strong>G\u00e9omembrane conductrice<\/strong><\/h3><p class=\"uagb-desc-text\">Une couche conductrice int\u00e9gr\u00e9e permet de localiser les fuites \u00e9lectriques (ELL) \u00e0 l'aide d'un test \u00e0 l'\u00e9tincelle pour un contr\u00f4le qualit\u00e9\/assurance qualit\u00e9 rapide sur les rev\u00eatements expos\u00e9s. Disponible en finition lisse ou textur\u00e9e, elle convient aux projets de confinement critiques en mati\u00e8re de contr\u00f4le qualit\u00e9.<\/p><\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div data-aos= \"fade-down\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" id=\"standardspecifications\" class=\"wp-block-uagb-container uagb-block-adc4298f alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a7e2c89f alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-baf71909\"><h2 class=\"uagb-heading-text\"><strong>Sp\u00e9cifications techniques (ASTM\/ISO) \u2014 S\u00e9lectionnez l'\u00e9paisseur<\/strong><\/h2><\/div>\n\n\n\n<div class=\"wp-block-uagb-tabs uagb-block-d10d3d4a uagb-tabs__wrap uagb-tabs__hstyle1-desktop uagb-tabs__vstyle6-tablet uagb-tabs__stack1-mobile\" data-tab-active=\"0\"><ul class=\"uagb-tabs__panel uagb-tabs__align-left\" role=\"tablist\"><li class=\"uagb-tab uagb-tabs__active\" role=\"none\"><a href=\"#uagb-tabs__tab0\" class=\"uagb-tabs-list uagb-tabs__icon-position-left\" data-tab=\"0\" role=\"tab\"><div>0,8 mm<\/div><\/a><\/li><li class=\"uagb-tab\" role=\"none\"><a href=\"#uagb-tabs__tab1\" class=\"uagb-tabs-list uagb-tabs__icon-position-left\" data-tab=\"1\" role=\"tab\"><div>1,0 mm<\/div><\/a><\/li><li class=\"uagb-tab\" role=\"none\"><a href=\"#uagb-tabs__tab2\" class=\"uagb-tabs-list uagb-tabs__icon-position-left\" data-tab=\"2\" role=\"tab\"><div>1,5 mm<\/div><\/a><\/li><\/ul><div class=\"uagb-tabs__body-wrap\">\n<div class=\"wp-block-uagb-tabs-child uagb-tabs__body-container uagb-inner-tab-0\" aria-labelledby=\"uagb-tabs__tab0\">\n<figure class=\"wp-block-flexible-table-block-table is-scroll-on-mobile is-style-default\"><table class=\"\" style=\"border-width:0;min-width:1200px\"><tbody><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Propri\u00e9t\u00e9<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong>M\u00e9thode d'essai<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong><strong>Valeur (m\u00e9trique)<\/strong><\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong>Imp\u00e9rial<\/strong><\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>\u00c9paisseur (moyenne minimale)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d5199-12r19.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM<\/a><a href=\"https:\/\/www.astm.org\/d5199.html\" target=\"_blank\" rel=\"noreferrer noopener\"> <\/a><a href=\"https:\/\/www.astm.org\/d5199-12r19.html\" target=\"_blank\" rel=\"noreferrer noopener\">D5199<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">0,80 mm<\/td><td style=\"width:25%;border-width:0 0 1px\">31,5 millions<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Densit\u00e9 (min.)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d1505.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D1505<\/a> \/ <a href=\"https:\/\/www.astm.org\/d0792.html\" target=\"_blank\" rel=\"noreferrer noopener\">D792<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 0,940 g\/cm\u00b3<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la traction \u00e0 la limite d'\u00e9lasticit\u00e9 (type IV)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d6693.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D6693<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 22 N\/mm<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 126 lb\/po<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la rupture (type IV)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d6693.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D6693<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 38 N\/mm<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 216 lb\/po<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Allongement \u00e0 la limite d'\u00e9lasticit\u00e9 \/ rupture<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d6693.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D6693<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 12% \/ \u2248 700%<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 12% \/ \u2248 700%<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la d\u00e9chirure<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d1004.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D1004<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 160 N<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 36 lbf<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Puncture d'index<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d4833_d4833m.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D4833<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 430 N<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 97 lbf<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance aux fissures sous contrainte (SP-NCTL)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d5397.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D5397 App.<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 500 h<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 500 h<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Temps d'induction oxydative (OIT standard)<\/strong><\/td><td style=\"border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d3895.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D3895<\/a><\/td><td style=\"border-width:0 0 1px\">\u2265 100 min<\/td><td style=\"border-width:0 0 1px\">\u2265 100 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>OIT haute pression (HP-OIT)<\/strong><\/td><td style=\"border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d5885_d5885m.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D5885<\/a><\/td><td style=\"border-width:0 0 1px\">\u2265 400 min<\/td><td style=\"border-width:0 0 1px\">\u2265 400 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Teneur en noir de carbone \/ Dispersion<\/strong><\/td><td style=\"border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d4218.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D4218<\/a> \/<a href=\"https:\/\/www.astm.org\/d5596.html\" target=\"_blank\" rel=\"noreferrer noopener\"> D5596<\/a><\/td><td style=\"border-width:0 0 1px\">2\u20133% \/ Cat\u00e9gorie 1\u20132<\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Indice de fluidit\u00e9 \u00e0 chaud (190 \u00b0C\/5 kg)<\/strong><\/td><td style=\"border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d1238.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D1238<\/a><\/td><td style=\"border-width:0 0 1px\">\u2264 1,0 g\/10 min<\/td><td style=\"border-width:0 0 1px\">\u2264 1,0 g\/10 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance des coutures \u2014 D\u00e9collement \/ Cisaillement<\/strong><\/td><td style=\"border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d6392.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D6392<\/a><\/td><td style=\"border-width:0 0 1px\">Pass (film d\u00e9chirable \/ coh\u00e9sif)<\/td><td style=\"border-width:0 0 1px\">Passe<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Hauteur de rugosit\u00e9 textur\u00e9e (si textur\u00e9e)<\/strong><\/td><td style=\"border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d7466_d7466m.html\" target=\"_blank\" rel=\"noreferrer noopener\">Proc\u00e9dure GM13 \/ ASTM D7466<\/a><\/td><td style=\"border-width:0 0 1px\">\u2248 0,5 \u00e0 1,0 mm<\/td><td style=\"border-width:0 0 1px\">\u2248 20 \u00e0 40 mil<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Interface \u00e0 cisaillement direct (remarque)<\/strong><\/td><td style=\"border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d5321_d5321m.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D5321<\/a><\/td><td style=\"border-width:0 0 1px\">Pr\u00e9cisez par projet (sol\/g\u00e9otextile)<\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Conductivit\u00e9 hydraulique (conception)<\/strong><\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><td style=\"border-width:0 0 1px\">~1\u00d710\u207b\u00b9\u00b3 m\/s (quasi imperm\u00e9able)<\/td><td style=\"border-width:0 0 1px\">~1\u00d710\u207b\u00b9\u2075 cm\/s<\/td><\/tr><\/tbody><\/table><figcaption>*Les valeurs indiqu\u00e9es sont des valeurs minimales types\/exemples utilis\u00e9es sur les feuilles de type GM13\/GM17 pour les rev\u00eatements en PEHD\/PEBDL ; les fiches techniques\/certificats d'analyse du produit r\u00e9el pr\u00e9valent. La r\u00e9sistance au cisaillement des joints et des interfaces d\u00e9pend du choix de la surface, du sol et du g\u00e9otextile.*<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-tabs-child uagb-tabs__body-container uagb-inner-tab-1\" aria-labelledby=\"uagb-tabs__tab1\">\n<figure class=\"wp-block-flexible-table-block-table is-scroll-on-mobile is-style-default\"><table class=\"\" style=\"border-width:0;min-width:1200px\"><tbody><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Propri\u00e9t\u00e9<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong>M\u00e9thode d'essai<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong><strong>Valeur (m\u00e9trique)<\/strong><\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong>Imp\u00e9rial<\/strong><\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>\u00c9paisseur (moyenne minimale)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D5199<\/td><td style=\"width:25%;border-width:0 0 1px\">1,00 mm<\/td><td style=\"width:25%;border-width:0 0 1px\">40 millim\u00e8tres<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Densit\u00e9 (min.)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D1505 \/ D792<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 0,940 g\/cm\u00b3<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la traction \u00e0 la limite d'\u00e9lasticit\u00e9 (type IV)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D6693<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 22 N\/mm<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 126 lb\/po<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la rupture (type IV)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D6693<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 42 N\/mm<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 240 lb\/po<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Allongement \u00e0 la limite d'\u00e9lasticit\u00e9 \/ rupture<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D6693<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 12% \/ \u2248 700%<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 12% \/ \u2248 700%<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la d\u00e9chirure<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D1004<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 175 N<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 39 lbf<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Puncture d'index<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D4833<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 460 N<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 103 lbf<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance aux fissures sous contrainte (SP-NCTL)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D5397 App.<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 500 h<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 500 h<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Temps d'induction oxydative (OIT standard)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D3895<\/td><td style=\"border-width:0 0 1px\">\u2265 100 min<\/td><td style=\"border-width:0 0 1px\">\u2265 100 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>OIT haute pression (HP-OIT)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D5885<\/td><td style=\"border-width:0 0 1px\">\u2265 400 min<\/td><td style=\"border-width:0 0 1px\">\u2265 400 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Teneur en noir de carbone \/ Dispersion<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D4218 \/ D5596<\/td><td style=\"border-width:0 0 1px\">2\u20133% \/ Cat\u00e9gorie 1\u20132<\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Indice de fluidit\u00e9 \u00e0 chaud (190 \u00b0C\/5 kg)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D1238<\/td><td style=\"border-width:0 0 1px\">\u2264 1,0 g\/10 min<\/td><td style=\"border-width:0 0 1px\">\u2264 1,0 g\/10 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance des coutures \u2014 D\u00e9collement \/ Cisaillement<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D6392<\/td><td style=\"border-width:0 0 1px\">Pass (film d\u00e9chirable \/ coh\u00e9sif)<\/td><td style=\"border-width:0 0 1px\">Passe<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Hauteur de rugosit\u00e9 textur\u00e9e (si textur\u00e9e)<\/strong><\/td><td style=\"border-width:0 0 1px\">Proc\u00e9dure GM13 \/ ASTM D7466<\/td><td style=\"border-width:0 0 1px\">\u2248 0,5 \u00e0 1,2 mm<\/td><td style=\"border-width:0 0 1px\">\u2248 20 \u00e0 47 millions<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Interface \u00e0 cisaillement direct (remarque)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D5321<\/td><td style=\"border-width:0 0 1px\">Pr\u00e9cisez par projet (sol\/g\u00e9otextile)<\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Conductivit\u00e9 hydraulique (conception)<\/strong><\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><td style=\"border-width:0 0 1px\">~1\u00d710\u207b\u00b9\u00b3 m\/s<\/td><td style=\"border-width:0 0 1px\">~1\u00d710\u207b\u00b9\u2075 cm\/s<\/td><\/tr><\/tbody><\/table><figcaption>*Les valeurs indiqu\u00e9es sont des valeurs minimales types\/exemples utilis\u00e9es sur les feuilles de type GM13\/GM17 pour les rev\u00eatements en PEHD\/PEBDL ; les fiches techniques\/certificats d'analyse du produit r\u00e9el pr\u00e9valent. La r\u00e9sistance au cisaillement des joints et des interfaces d\u00e9pend du choix de la surface, du sol et du g\u00e9otextile.*<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-tabs-child uagb-tabs__body-container uagb-inner-tab-2\" aria-labelledby=\"uagb-tabs__tab2\">\n<figure class=\"wp-block-flexible-table-block-table is-scroll-on-mobile is-style-default\"><table class=\"\" style=\"border-width:0;min-width:1200px\"><tbody><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Propri\u00e9t\u00e9<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong>M\u00e9thode d'essai<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong><strong>Valeur (m\u00e9trique)<\/strong><\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><strong>Imp\u00e9rial<\/strong><\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>\u00c9paisseur (moyenne minimale)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d5199-12r19.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D5199<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">1,50 mm<\/td><td style=\"width:25%;border-width:0 0 1px\">60 mil<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Densit\u00e9 (min.)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d1505-18.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D1505<\/a> \/<a href=\"https:\/\/www.astm.org\/d0792-20.html\" target=\"_blank\" rel=\"noreferrer noopener\"> D792<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 0,940 g\/cm\u00b3<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la traction \u00e0 la limite d'\u00e9lasticit\u00e9 (type IV)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d6693-04r15e01.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D6693<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 22 N\/mm<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 126 lb\/po<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la rupture (type IV)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d6693-04r15e01.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D6693<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 40 N\/mm<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 228 lb\/po<\/td><\/tr><tr><td style=\"width:25%;border-width:0 0 1px;text-align:left\"><strong>Allongement \u00e0 la limite d'\u00e9lasticit\u00e9 \/ rupture<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\"><a href=\"https:\/\/www.astm.org\/d6693-04r15e01.html\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D6693<\/a><\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 12% \/ \u2248 700%<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2248 12% \/ \u2248 700%<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance \u00e0 la d\u00e9chirure<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D1004<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 187 N<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 42 lbf<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Puncture d'index<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D4833<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 480 N<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 108 lbf<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance aux fissures sous contrainte (SP-NCTL)<\/strong><\/td><td style=\"width:25%;border-width:0 0 1px\">ASTM D5397 App.<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 500 h<\/td><td style=\"width:25%;border-width:0 0 1px\">\u2265 500 h<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Temps d'induction oxydative (OIT standard)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D3895<\/td><td style=\"border-width:0 0 1px\">\u2265 100 min<\/td><td style=\"border-width:0 0 1px\">\u2265 100 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>OIT haute pression (HP-OIT)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D5885<\/td><td style=\"border-width:0 0 1px\">\u2265 400 min<\/td><td style=\"border-width:0 0 1px\">\u2265 400 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Teneur en noir de carbone \/ Dispersion<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D4218 \/ D5596<\/td><td style=\"border-width:0 0 1px\">2\u20133% \/ Cat\u00e9gorie 1\u20132<\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Indice de fluidit\u00e9 \u00e0 chaud (190 \u00b0C\/5 kg)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D1238<\/td><td style=\"border-width:0 0 1px\">\u2264 1,0 g\/10 min<\/td><td style=\"border-width:0 0 1px\">\u2264 1,0 g\/10 min<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>R\u00e9sistance des coutures \u2014 D\u00e9collement \/ Cisaillement<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D6392<\/td><td style=\"border-width:0 0 1px\">Pass (film d\u00e9chirable \/ coh\u00e9sif)<\/td><td style=\"border-width:0 0 1px\">Passe<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Hauteur de rugosit\u00e9 textur\u00e9e (si textur\u00e9e)<\/strong><\/td><td style=\"border-width:0 0 1px\">Proc\u00e9dure GM13 \/ ASTM D7466<\/td><td style=\"border-width:0 0 1px\">\u2248 0,5 \u00e0 1,5 mm<\/td><td style=\"border-width:0 0 1px\">\u2248 20 \u00e0 60 mil<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Interface \u00e0 cisaillement direct (remarque)<\/strong><\/td><td style=\"border-width:0 0 1px\">ASTM D5321<\/td><td style=\"border-width:0 0 1px\">Pr\u00e9cisez par projet (sol\/g\u00e9otextile)<\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><\/tr><tr><td style=\"border-width:0 0 1px;text-align:left\"><strong>Conductivit\u00e9 hydraulique (conception)<\/strong><\/td><td style=\"border-width:0 0 1px\">\u2014<\/td><td style=\"border-width:0 0 1px\">~1\u00d710\u207b\u00b9\u00b3 m\/s<\/td><td style=\"border-width:0 0 1px\">~1\u00d710\u207b\u00b9\u2075 cm\/s<\/td><\/tr><\/tbody><\/table><figcaption>*Les valeurs indiqu\u00e9es sont des valeurs minimales types\/exemples utilis\u00e9es sur les feuilles de type GM13\/GM17 pour les rev\u00eatements en PEHD\/PEBDL ; les fiches techniques\/certificats d'analyse du produit r\u00e9el pr\u00e9valent. La r\u00e9sistance au cisaillement des joints et des interfaces d\u00e9pend du choix de la surface, du sol et du g\u00e9otextile.*<\/figcaption><\/figure>\n<\/div>\n<\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-81782f98 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a06f3da0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-03dd0e46\"><h2 class=\"uagb-heading-text\"><strong>Applications<\/strong><\/h2><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-747f5a73 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-129a65f8\">\n<div class=\"wp-block-uagb-image uagb-block-1941c19d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Mining-Heap-Leach-1024x768.webp ,https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Mining-Heap-Leach.webp 780w, https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Mining-Heap-Leach.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Mining-Heap-Leach-1024x768.webp\" alt=\"Installation d&#039;une membrane g\u00e9omembrane en PEHD pour le confinement d&#039;un pad de lixiviation mini\u00e8re et la collecte de solution\" class=\"uag-image-5749\" width=\"942\" height=\"707\" title=\"Installation d&#039;une membrane g\u00e9omembrane en PEHD pour le confinement d&#039;un pad de lixiviation mini\u00e8re et la collecte de solution\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-43dd06dc\"><div class=\"uagb-heading-text\">Exploitation mini\u00e8re \u2013 Lixiviation en tas<\/div><p class=\"uagb-desc-text\">Rev\u00eatements en PEHD\/PEBDL r\u00e9sistants aux produits chimiques pour les plateformes de lixiviation en tas, les bassins de solution et les zones ADR ; la couleur blanche\/noire r\u00e9duit la chaleur dans les sites arides.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-41f4e296\">\n<div class=\"wp-block-uagb-image uagb-block-7a247cb7 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Water-Irrigation.webp ,https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Water-Irrigation.webp 780w, https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Water-Irrigation.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/Water-Irrigation.webp\" alt=\"Rev\u00eatement imperm\u00e9able en g\u00e9omembrane pour r\u00e9servoirs d&#039;irrigation agricole et canaux d&#039;irrigation\" class=\"uag-image-5750\" width=\"301\" height=\"207\" title=\"Rev\u00eatement imperm\u00e9able en g\u00e9omembrane pour r\u00e9servoirs d&#039;irrigation agricole et canaux d&#039;irrigation\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-2b75168b\"><div class=\"uagb-heading-text\">Eau et irrigation<\/div><p class=\"uagb-desc-text\">R\u00e9servoirs, canaux et bassins d'irrigation ; conception conforme \u00e0 la norme EN 13361\/13362, le cas \u00e9ch\u00e9ant.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6ad60b98\">\n<div class=\"wp-block-uagb-image uagb-block-561d1067 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/WWTP-Industrial.webp ,https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/WWTP-Industrial.webp 780w, https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/WWTP-Industrial.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/WWTP-Industrial.webp\" alt=\"Rev\u00eatement en PEHD r\u00e9sistant aux produits chimiques pour bassins de traitement des eaux us\u00e9es industrielles et confinement secondaire\" class=\"uag-image-5751\" width=\"296\" height=\"204\" title=\"Rev\u00eatement en PEHD r\u00e9sistant aux produits chimiques pour bassins de traitement des eaux us\u00e9es industrielles et confinement secondaire\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-087a4038\"><div class=\"uagb-heading-text\">STT et industriel<\/div><p class=\"uagb-desc-text\">Eau de traitement, lagunes, confinement secondaire et parcs de stockage ; v\u00e9rifier la compatibilit\u00e9 chimique pour des milieux sp\u00e9cifiques.<\/p><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-2648a006\">\n<div class=\"wp-block-uagb-image uagb-block-c7788e85 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/12\/1000111.png ,https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/12\/1000111.png 780w, https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/12\/1000111.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/12\/1000111.png\" alt=\"Installation d&#039;une membrane g\u00e9omembrane imperm\u00e9able en LLDPE enveloppant des r\u00e9servoirs souterrains g\u00e9ocellulaires de r\u00e9tention des eaux pluviales.\" class=\"uag-image-7186\" width=\"301\" height=\"178\" title=\"10001(1)(1)\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-dea74294\"><div class=\"uagb-heading-text\"><strong>Enveloppe pour r\u00e9servoir d'eaux pluviales<\/strong><\/div><p class=\"uagb-desc-text\">Enveloppe imperm\u00e9able en LLDPE pour r\u00e9servoirs g\u00e9ocellulaires. Garantit des syst\u00e8mes de r\u00e9tention \u00e9tanches et z\u00e9ro fuite pour les projets de r\u00e9utilisation de l'eau.<\/p><\/div>\n<\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div data-aos= \"fade-down\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-bb470918 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-7199a958 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-1c594371\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-c189dd1a\"><h2 class=\"uagb-heading-text\"><strong><strong>Assemblage, essais et assurance qualit\u00e9\/contr\u00f4le qualit\u00e9<\/strong><\/strong><\/h2><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Soudage : soudage \u00e0 coin chaud \u00e0 double piste pour les joints de production ; soudage par extrusion pour les d\u00e9tails, les rustines et les raccords.<\/li>\n\n\n\n<li>Essais destructifs : pelage et cisaillement selon la norme ASTM D6392 sur des coupons pr\u00e9lev\u00e9s sur le terrain.<\/li>\n\n\n\n<li>Essais non destructifs : bo\u00eete \u00e0 vide (ASTM D5641) et essai de pression dans un canal d'air (coutures \u00e0 double voie) ; \u00e9tincelle\/EL pour les rev\u00eatements conducteurs (ASTM D7240\/D7007).<\/li>\n\n\n\n<li>Localisation des fuites : contr\u00f4les \u00e9lectriques des rev\u00eatements couverts\/expos\u00e9s conform\u00e9ment aux normes ASTM D7007\/D7702.<\/li>\n\n\n\n<li>Contr\u00f4le du processus : r\u00e9sine vierge \u2265 97% avec 2\u20133% de noir de carbone ; contr\u00f4le de l'\u00e9paisseur en ligne ; contr\u00f4le qualit\u00e9 r\u00e9gulier conforme aux normes GRI GM13\/GM17.<\/li>\n\n\n\n<li>Syst\u00e8mes et documentation : syst\u00e8mes de fabrication certifi\u00e9s ISO 9001\/14001\/45001 ; cartes de laminage, \u00e9tiquettes et certificats d'analyse\/assurance qualit\u00e9 disponibles sur demande.<\/li>\n<\/ul>\n\n\n\n<p>Les certificats d'analyse (CoA), les r\u00e9sultats des tests de conformit\u00e9 et les audits d'usine peuvent \u00eatre fournis sur demande dans le cadre des soumissions.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-98ae53ea\">\n<div class=\"wp-block-uagb-image uagb-block-7e49ed40 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/InstallationQAQC.webp ,https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/InstallationQAQC.webp 780w, https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/InstallationQAQC.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/spcdn.shortpixel.ai\/spio\/ret_img,q_cdnize,to_auto,s_webp:avif\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/InstallationQAQC.webp\" alt=\"Installation d&#039;une g\u00e9omembrane \u00e0 l&#039;aide d&#039;un soudage \u00e0 coin chaud et test de pression d&#039;air pour l&#039;assurance qualit\u00e9\/le contr\u00f4le qualit\u00e9 de l&#039;int\u00e9grit\u00e9 des joints\" class=\"uag-image-5755\" width=\"1024\" height=\"684\" title=\"Installation d&#039;une g\u00e9omembrane \u00e0 l&#039;aide d&#039;un soudage \u00e0 coin chaud et test de pression d&#039;air pour l&#039;assurance qualit\u00e9\/le contr\u00f4le qualit\u00e9 de l&#039;int\u00e9grit\u00e9 des joints\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div data-aos= \"fade-down\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-eec6f6ad alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-edd06f71\"><h2 class=\"uagb-heading-text\"><strong>Devenez notre partenaire. Faible investissement. Rendement \u00e9lev\u00e9. Assistance compl\u00e8te.<\/strong><\/h2><p class=\"uagb-desc-text\">Distribuez et installez nos solutions techniques pour l'eau et le sol, avec une assistance technique compl\u00e8te, des outils marketing et l'acc\u00e8s \u00e0 des prospects qualifi\u00e9s.<\/p><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__medium-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-1c41bc62\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap\">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-5c7a3bd7 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/aquarainwater.com\/fr\/distributeur\/\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">Devenir partenaire<\/div><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-772d8bf0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-096f0871\"><h2 class=\"uagb-heading-text\"><strong><strong>FAQ<\/strong><\/strong><\/h2><\/div>\n\n\n<div class=\"wp-block-uagb-faq uagb-faq__outer-wrap uagb-block-116d7986 uagb-faq-icon-row-reverse uagb-faq-layout-accordion uagb-faq-expand-first-true uagb-faq-inactive-other-true uagb-faq__wrap uagb-buttons-layout-wrap uagb-faq-equal-height\" data-faqtoggle=\"true\" role=\"tablist\"><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-0e3f01fe\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong><strong>Quels sont les principaux avantages li\u00e9s \u00e0 l'utilisation de vos g\u00e9omembranes ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Nos g\u00e9omembranes sont tr\u00e8s durables, r\u00e9sistantes aux produits chimiques et stabilis\u00e9es aux UV pour une performance longue dur\u00e9e. Elles sont id\u00e9ales pour les d\u00e9charges, les mines, le confinement d'eau et le confinement secondaire. Gr\u00e2ce \u00e0 nos options HDPE et LLDPE, vous b\u00e9n\u00e9ficiez d'une flexibilit\u00e9 et d'une r\u00e9sistance sup\u00e9rieures pour les installations expos\u00e9es et enfouies.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-21a324a5\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong>Quelle \u00e9paisseur choisir pour mon projet ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Les \u00e9paisseurs courantes sont 1,0 mm (40 mil), 1,5 mm (60 mil) et 2,0 mm (80 mil). L'\u00e9paisseur dont vous avez besoin d\u00e9pend de facteurs tels que la r\u00e9sistance \u00e0 la perforation, les risques de soul\u00e8vement et la dur\u00e9e de vie pr\u00e9vue de votre projet. Pour les d\u00e9charges, une \u00e9paisseur \u2265 60 mil (1,5 mm) est g\u00e9n\u00e9ralement requise, tandis que pour les conteneurs secondaires ou les rev\u00eatements de lagunes, des options plus fines peuvent convenir.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-e266aa08\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong>Proposez-vous des tailles et des formes personnalis\u00e9es ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Oui, nous proposons des largeurs personnalis\u00e9es allant jusqu'\u00e0 8,0 m (\u2248 26 pieds) et pouvons offrir diff\u00e9rentes longueurs pour r\u00e9pondre aux exigences de votre projet. Nos rouleaux sont con\u00e7us pour minimiser les joints et rendre l'installation plus rapide et plus facile. Des cartes en rouleaux et des dimensions sp\u00e9cifiques sont disponibles sur demande.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-c4b39634\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong>Comment vos g\u00e9omembranes sont-elles install\u00e9es ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Nos g\u00e9omembranes sont faciles \u00e0 installer \u00e0 l'aide de m\u00e9thodes de soudage \u00e0 coin chaud ou par extrusion. Les joints sur site sont test\u00e9s \u00e0 l'aide de m\u00e9thodes de bo\u00eete \u00e0 vide et de canal d'air (pour les essais non destructifs) et d'essais de pelage\/cisaillement (selon la norme ASTM D6392) afin de garantir l'int\u00e9grit\u00e9 des joints. Nous proposons \u00e9galement des essais d'\u00e9tincelage pour les rev\u00eatements conducteurs.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-bbf1b586\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong><strong>Comment puis-je \u00eatre s\u00fbr que vos g\u00e9omembranes sont conformes aux normes et r\u00e9glementations ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Nous fournissons une documentation compl\u00e8te et une certification pour toutes nos g\u00e9omembranes. Elles sont test\u00e9es pour r\u00e9pondre aux normes ASTM D6392, GRI GM13\/GM17, EPA Subtitle D (pour les d\u00e9charges) et EN 13361\/EN 13491. Nous fournissons \u00e9galement une fabrication certifi\u00e9e ISO 9001 pour l'assurance qualit\u00e9.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-3e053722\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong><strong>Pouvez-vous nous aider avec les tests effectu\u00e9s par des tiers ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Oui, nous pouvons coordonner des tests ind\u00e9pendants r\u00e9alis\u00e9s par des tiers pour des propri\u00e9t\u00e9s cl\u00e9s telles que la r\u00e9sistance \u00e0 la traction, le temps d'induction oxydative (OIT) et la r\u00e9sistance aux fissures sous contrainte. Des rapports d'assurance qualit\u00e9 complets, des certificats d'analyse (COA) et des plans d'assurance qualit\u00e9 de la construction (CQA) peuvent \u00eatre fournis afin de garantir la conformit\u00e9 et la qualit\u00e9 tout au long de votre projet.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-cc49b104\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong><strong>Quelles sont les options de livraison disponibles et les d\u00e9lais d'ex\u00e9cution ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Nous proposons des options d'exp\u00e9dition flexibles pour r\u00e9pondre \u00e0 vos d\u00e9lais. Les rouleaux standard mesurent g\u00e9n\u00e9ralement entre 7,0 et 7,5 m (\u2248 23 \u00e0 25 pieds) de largeur, avec des longueurs allant de 90 \u00e0 170 m (\u2248 300 \u00e0 560 pieds), selon l'\u00e9paisseur. Les d\u00e9lais de livraison d\u00e9pendent des sp\u00e9cifications du projet et du volume de la commande ; nous vous communiquerons les d\u00e9lais exacts au moment de la commande.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-413f6977\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong><strong><strong>Quels sont les facteurs de co\u00fbt des g\u00e9omembranes ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Le co\u00fbt des g\u00e9omembranes d\u00e9pend de leur \u00e9paisseur, du type de surface (lisse ou textur\u00e9e), de la quantit\u00e9 de mat\u00e9riau n\u00e9cessaire et des caract\u00e9ristiques sp\u00e9cialis\u00e9es (comme les rev\u00eatements conducteurs pour les tests d'\u00e9tincelles). Nous proposons des prix comp\u00e9titifs et sommes heureux de vous fournir un devis en fonction de vos besoins sp\u00e9cifiques.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-56e14fe7\" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M310.6 246.6l-127.1 128C176.4 380.9 168.2 384 160 384s-16.38-3.125-22.63-9.375l-127.1-128C.2244 237.5-2.516 223.7 2.438 211.8S19.07 192 32 192h255.1c12.94 0 24.62 7.781 29.58 19.75S319.8 237.5 310.6 246.6z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox= \"0 0 320 512\"><path d=\"M27.66 224h264.7c24.6 0 36.89-29.78 19.54-47.12l-132.3-136.8c-5.406-5.406-12.47-8.107-19.53-8.107c-7.055 0-14.09 2.701-19.45 8.107L8.119 176.9C-9.229 194.2 3.055 224 27.66 224z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<span class=\"uagb-question\"><strong><strong><strong><strong><strong><strong><strong><strong><strong>Pourquoi devrais-je choisir vos g\u00e9omembranes plut\u00f4t que celles d'autres marques ?<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/span><\/div><div class=\"uagb-faq-content\"><p>Nos g\u00e9omembranes sont fabriqu\u00e9es \u00e0 partir de r\u00e9sine vierge, offrant une durabilit\u00e9, une r\u00e9sistance chimique et une flexibilit\u00e9 sup\u00e9rieures. Gr\u00e2ce \u00e0 une fabrication certifi\u00e9e ISO et \u00e0 la conformit\u00e9 aux normes internationales telles que l'ASTM et la GRI, nous garantissons des produits de qualit\u00e9 sup\u00e9rieure pour des applications exigeantes telles que les d\u00e9charges, l'exploitation mini\u00e8re et le confinement de l'eau. Nous fournissons \u00e9galement un excellent service apr\u00e8s-vente et une documentation compl\u00e8te pour faciliter votre projet.<\/p><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>HDPE &amp; LLDPE Geomembrane Liners for Stormwater Detention, Landfill &amp; Mining Robust HDPE and LLDPE geomembranes for landfill cells, heap leach pads, wastewater containment, and secondary containment. Designed to meet [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":3071,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"full-width-container","site-content-style":"unboxed","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-4883","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HDPE &amp; LLDPE Geomembrane Liners for Stormwater Detention<\/title>\n<meta name=\"description\" content=\"High-quality HDPE &amp; LLDPE geomembranes for wrapping underground stormwater tanks. Impermeable, puncture-resistant liners tested to GRI GM13\/GM17 standards.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/aquarainwater.com\/fr\/produits\/geomembranes\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HDPE &amp; LLDPE Geomembrane Liners for Stormwater Detention\" \/>\n<meta property=\"og:description\" content=\"High-quality HDPE &amp; LLDPE geomembranes for wrapping underground stormwater tanks. Impermeable, puncture-resistant liners tested to GRI GM13\/GM17 standards.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/aquarainwater.com\/fr\/produits\/geomembranes\/\" \/>\n<meta property=\"og:site_name\" content=\"Aquarainwater\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-12T07:40:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/aquarainwater.com\/products\/geomembranes\/\",\"url\":\"https:\/\/aquarainwater.com\/products\/geomembranes\/\",\"name\":\"HDPE & LLDPE Geomembrane Liners for Stormwater Detention\",\"isPartOf\":{\"@id\":\"https:\/\/aquarainwater.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/aquarainwater.com\/products\/geomembranes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/aquarainwater.com\/products\/geomembranes\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp\",\"datePublished\":\"2025-10-04T01:21:49+00:00\",\"dateModified\":\"2025-12-12T07:40:27+00:00\",\"description\":\"High-quality HDPE & LLDPE geomembranes for wrapping underground stormwater tanks. Impermeable, puncture-resistant liners tested to GRI GM13\/GM17 standards.\",\"breadcrumb\":{\"@id\":\"https:\/\/aquarainwater.com\/products\/geomembranes\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/aquarainwater.com\/products\/geomembranes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/aquarainwater.com\/products\/geomembranes\/#primaryimage\",\"url\":\"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp\",\"contentUrl\":\"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/aquarainwater.com\/products\/geomembranes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"HOME\",\"item\":\"https:\/\/aquarainwater.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/aquarainwater.com\/es\/productos\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Geomembranes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/aquarainwater.com\/#website\",\"url\":\"https:\/\/aquarainwater.com\/\",\"name\":\"Underground Stormwater Detention & Infiltration Solutions Expert | Flood Mitigation & LID\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/aquarainwater.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/aquarainwater.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/aquarainwater.com\/#organization\",\"name\":\"ARW Stormwater Management\",\"url\":\"https:\/\/aquarainwater.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/aquarainwater.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-\u5fae\u4fe1\u56fe\u7247_20250827165723_16_579.png\",\"contentUrl\":\"https:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-\u5fae\u4fe1\u56fe\u7247_20250827165723_16_579.png\",\"width\":514,\"height\":224,\"caption\":\"ARW Stormwater Management\"},\"image\":{\"@id\":\"https:\/\/aquarainwater.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.cn\/incareer\/company\/arw-stormwater-management\/\",\"https:\/\/wa.me\/85267102428\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Geomembranes en PEHD et PEHD-L pour la r\u00e9tention des eaux pluviales","description":"G\u00e9omembranes HDPE et LLDPE de haute qualit\u00e9 pour l'enrobage des r\u00e9servoirs souterrains d'eaux pluviales. Rev\u00eatements imperm\u00e9ables et r\u00e9sistants \u00e0 la perforation, test\u00e9s selon les normes GRI GM13\/GM17.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/aquarainwater.com\/fr\/produits\/geomembranes\/","og_locale":"fr_FR","og_type":"article","og_title":"HDPE & LLDPE Geomembrane Liners for Stormwater Detention","og_description":"High-quality HDPE & LLDPE geomembranes for wrapping underground stormwater tanks. Impermeable, puncture-resistant liners tested to GRI GM13\/GM17 standards.","og_url":"https:\/\/aquarainwater.com\/fr\/produits\/geomembranes\/","og_site_name":"Aquarainwater","article_modified_time":"2025-12-12T07:40:27+00:00","og_image":[{"url":"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/aquarainwater.com\/products\/geomembranes\/","url":"https:\/\/aquarainwater.com\/products\/geomembranes\/","name":"Geomembranes en PEHD et PEHD-L pour la r\u00e9tention des eaux pluviales","isPartOf":{"@id":"https:\/\/aquarainwater.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/aquarainwater.com\/products\/geomembranes\/#primaryimage"},"image":{"@id":"https:\/\/aquarainwater.com\/products\/geomembranes\/#primaryimage"},"thumbnailUrl":"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp","datePublished":"2025-10-04T01:21:49+00:00","dateModified":"2025-12-12T07:40:27+00:00","description":"G\u00e9omembranes HDPE et LLDPE de haute qualit\u00e9 pour l'enrobage des r\u00e9servoirs souterrains d'eaux pluviales. Rev\u00eatements imperm\u00e9ables et r\u00e9sistants \u00e0 la perforation, test\u00e9s selon les normes GRI GM13\/GM17.","breadcrumb":{"@id":"https:\/\/aquarainwater.com\/products\/geomembranes\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/aquarainwater.com\/products\/geomembranes\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/aquarainwater.com\/products\/geomembranes\/#primaryimage","url":"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp","contentUrl":"http:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/10\/geomembranesbanner.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/aquarainwater.com\/products\/geomembranes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"HOME","item":"https:\/\/aquarainwater.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/aquarainwater.com\/es\/productos\/"},{"@type":"ListItem","position":3,"name":"Geomembranes"}]},{"@type":"WebSite","@id":"https:\/\/aquarainwater.com\/#website","url":"https:\/\/aquarainwater.com\/","name":"Expert en solutions de r\u00e9tention et d'infiltration des eaux pluviales souterraines - Att\u00e9nuation des inondations et am\u00e9nagement du territoire","description":"","publisher":{"@id":"https:\/\/aquarainwater.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/aquarainwater.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/aquarainwater.com\/#organization","name":"Gestion des eaux pluviales ARW","url":"https:\/\/aquarainwater.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/aquarainwater.com\/#\/schema\/logo\/image\/","url":"https:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-\u5fae\u4fe1\u56fe\u7247_20250827165723_16_579.png","contentUrl":"https:\/\/aquarainwater.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-\u5fae\u4fe1\u56fe\u7247_20250827165723_16_579.png","width":514,"height":224,"caption":"ARW Stormwater Management"},"image":{"@id":"https:\/\/aquarainwater.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.cn\/incareer\/company\/arw-stormwater-management\/","https:\/\/wa.me\/85267102428"]}]}},"taxonomy_info":[],"featured_image_src_large":false,"author_info":{"display_name":"aquarainwater","author_link":"https:\/\/aquarainwater.com\/fr\/author\/hong\/"},"comment_info":0,"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"aquarainwater","author_link":"https:\/\/aquarainwater.com\/fr\/author\/hong\/"},"uagb_comment_info":0,"uagb_excerpt":"HDPE &amp; LLDPE Geomembrane Liners for Stormwater Detention, Landfill &amp; Mining Robust HDPE and LLDPE geomembranes for landfill cells, heap leach pads, wastewater containment, and secondary containment. Designed to meet [&hellip;]","_links":{"self":[{"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/pages\/4883","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/comments?post=4883"}],"version-history":[{"count":70,"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/pages\/4883\/revisions"}],"predecessor-version":[{"id":7187,"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/pages\/4883\/revisions\/7187"}],"up":[{"embeddable":true,"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/pages\/3071"}],"wp:attachment":[{"href":"https:\/\/aquarainwater.com\/fr\/wp-json\/wp\/v2\/media?parent=4883"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}